top of page

Rail
Rail DAS Solutions
Rail tunnel DAS solutions are either off-air repeater or dedicated base station fed. Off-air repeaters are used in remote locations for both TETRA and GSM-R where the off-air signal is strong and the capacity requirements are low.
The appropriate approach depends on frequency, tunnel characteristics, available signal and performance requirements. In many applications although not a fixed rule, a simple off air repeater can feed the signal into a short tunnel (<500m).
Longer tunnels (>500m) again the approach will need to be designed for the specific location, an off-air repeater may feed a number of remote amplifiers distributed along the tunnel providing continuous coverage. The transmission can be either antenna based or more typically radiating cable (leaky feeder).
Initially we will provide a desktop review of the tunnel topography and customer coverage requirements to determine antenna / equipment locations and potential problem zones. Careful consideration will be given to handover zones at the tunnel portals.
Antennas are a simple low-cost solution for a single band of operation; however, they can suffer from near / far effect of signal distribution in the tunnel and can easily be blocked in narrow tunnels by large vehicles. Radiating cable offers a controlled predictable signal level along the length between sources of feed. It is wide band and can accommodate most frequencies from multiple combined sources across a wide spectrum. It offers good protection from the tunnel environment but it does have a high impact on the installation time and cost.